Quality Oilfield Products

MD-U Gate Valve Operational Data

The gate valve should always be in either full-open or full-closed postition. Leavign the gate valve partially open or throttling through the gate valve could result in damage to the gates and seats.

1. The valve is opened by turning the handwheel counterclockwise until it stops, then backing off 1/4 turn to relieve any stress in the operating mechanism.

2. The valve is closed by turning the hand wheel clockwise until it stops, then backing off 1/4 to 1/2 turn to allow the gate to seal. The required torque may increase for the last few turns if there is a pressure differential across the gate.

Back to Valves

2000-3000 PSI Working Pressure

Size

2-1/16"

2-9/16"

3-1/8"

4-1/16"

5-1/8"

6-3/8"

Anticipated Torque

15

20

25

30

45

80

Maximum Torque

30

40

60

80

130

235

Turns to Open/Close

12-1/3

15-1/8

18-1/8

23-1/4

27-1/2

33-3/4

5000 PSI Working Pressure

Size

2-1/16"

2-9/16"

3-1/8"

4-1/16"

5-1/8"

6-3/8"

Anticipated Torque

20

25

35

50

75

140

Maximum Torque

45

65

95

135

220

395

Turns to Open/Close

12-1/3

15-1/8

18-1/8

23-1/4

27-1/2

33-3/4

10,000 PSI Working Pressure

Size

1-13/16"

2-1/16"

2-9/16"

3-1/16"

4-1/16"

5-1/8"

Anticipated Torque

30

30

35

50

65

110

Maximum Torque

80

80

85

130

170

320

Turns to Open/Close

12-1/3

12-1/3

12-1/3

15-1/8

18-1/8

23-1/4

15,000 PSI Working Pressure

Size

1-13/16"

2-1/16"

2-9/16"

3-1/16"

Anticipated Torque

50

15

20

25

Maximum Torque

125

30

40

60

Turns to Open/Close

12-1/3

12-1/3

15-1/8

18-1/8