Quality Oilfield Products

MD-W Gate Valve

The gate valve should always be in either full-open or full-closed postition. Leaving the gate valve partially open or throttling through the gate valve could result in damage to the gates and seats.

1. The valve is opened by turning the handwheel counterclockwise until it stops, then backing off 1/4 turn to relieve any stress in the operating mechanism.

2. The valve is closed by turning the hand wheel clockwise until it stops, then backing off 1/4 to 1/2 turn to allow the gate to seal. The required torque may increase for the last few turns if there is a pressure differential across the gate.

Back to Valves

No of Valve Revolutions

Input Torque

Size

To Fully Open/Close

To Crack Open

Before Cracked Open

After Cracked Open

ft-lb

n*m

ft-lb

n*m

3-1/16", 20k psi

15-3/4

3-1/3

112

152

22

30

4-1/6", 15k psi

19

2-1/2

102

138

16

22

4-1/16", 20k

21

4-1/2

177

240

22

30

5-1/8", 10k

23-1/4

2-1/2

102

138

12

16

5-1/8", 15k

24

3

176

239

16

22

6-3/8", 10k

28-3/4

3

150

204

15

21

6-3/8", 15k

15-1/4

2-1/2

401

544

21

29

7-1/16", 10k

31

2-1/2

181

245

15

21

7-1/16", 15k

16-5/8

2-1/2

451

612

21

29

9", 5k

38-1/4

3

125

170

21

28

9", 10k

20

2

381

516

21

28